VERITAS ENVIRONMENT · CHEMICAL AND PROCESS INDUSTRY

Chemical and Process Industry Wastewater Treatment and Recovery Systems

On-Site Treatment of Process Wastewater with High Disposal Costs

Wastewater generated in chemical and process industries may contain high COD, solvents, alcohols, surfactants, oils, emulsions, color, salts, metals and substances that inhibit biological treatment, depending on the products, raw materials, production formulations and cleaning procedures used.

High-strength wastewater that does not meet discharge criteria or biological treatment acceptance requirements is often transported off site at substantial transportation and disposal costs.

VERITAS ENVIRONMENT develops tailored process systems for on-site treatment by evaluating wastewater streams separately according to their source and composition. The treated water is brought into compliance with direct discharge criteria, biological treatment acceptance requirements or, where suitable, reuse quality targets.

Hybrid photocatalytic oxidation technology developed through TÜBİTAK-supported R&D aims to reduce high organic loads and recalcitrant constituents, lower the amount of wastewater transported off site and strengthen existing treatment infrastructure.

Request a Preliminary Technical Assessment ↗Explore the Treatment Process ↓
TÜBİTAK-supported R&DHybrid photocatalytic oxidationTurnkey systems
Industrial tanks and process piping representing chemical manufacturing infrastructure
CHEMICAL & PROCESS MANUFACTURING
Industrial paint and pigment mixing unit
Paint and pigment production
Laboratory professional conducting chemical analysis
Analysis and process control
Source managementDedicated processes based on wastewater characteristics
Hybrid oxidationManaging recalcitrant organic loads
On-site treatmentDischarge and biological treatment targets
Modular engineeringIntegration into existing plants
01 · PROCESS APPROACH

How Is Chemical Industry Wastewater Treated?

The treatment process for chemical wastewater is determined by its source, constituent substances, pollutant load, biodegradability and target effluent quality.

The general process approach consists of the following stages:

01
Separate management at source

High- and low-strength process wastewater streams are identified and directed to appropriate collection and treatment lines.

02
Equalization and controlled feeding

Variations in flow rate, pH, temperature, conductivity and organic load are equalized.

03
Physicochemical pretreatment

Oils, emulsions, suspended solids, colloidal constituents and, when necessary, metal loads are reduced.

04
Hybrid photocatalytic oxidation

High COD, toxicity and recalcitrant organic compounds are controlled.

05
Biological treatment

Organic loads in wastewater with improved biodegradability are reduced using existing or newly installed biological treatment systems.

06
Final treatment and quality control

Effluent undergoes filtration and any required advanced treatment to meet discharge, biological treatment or reuse targets.

The treatment stages required for each project are configured to achieve target water quality with optimal capital and operating costs.

02 · PRODUCTION SOURCES

Wastewater Sources in the Chemical and Process Industry

Wastewater in chemical manufacturing plants may originate mainly from the following operations:

Industrial steel mixing and process tanks
Reactors and production tanks
Color mixing machine used in industrial paint production
Paint, pigments and coatings
Chemical manufacturing storage and process tanks
Storage and transfer lines
Washing reactors, mixers and production tanks
First washes and rinses during product changeovers
Cleaning filling lines, pipes and transfer equipment
CIP systems
Washing raw-material and product storage tanks
Cleaning filters, separators and process equipment
Production water containing oils, resins, polymers and emulsions
Water containing paints, pigments, coatings and surfactants
Process and cleaning water containing alcohols and solvents
Wastewater from gas washing and scrubber systems
Off-specification products and concentrated product residues
Cleaning production areas and floors
Process water from auxiliary operations

Managing high-concentration first-wash water separately from lower-strength rinse water directly improves treatment capacity and operating economics.

03 · WASTEWATER CHARACTERIZATION

Main Treatment Challenges in Chemical Wastewater

High and Variable COD

Product residues released during reactor, tank and filling-line cleaning can generate high organic loads within a short period. COD can fluctuate considerably during the day because of differences between production formulations.

Equalization, controlled feeding and staged treatment help keep the system stable during sudden load changes.

Substances That Inhibit Biological Treatment

Biocidal agents, specialty additives, reaction by-products and certain chemicals may interfere with microbial activity during biological treatment.

Separately managing such water and applying suitable advanced oxidation before biological treatment reduces toxic and inhibitory effects.

Alcohol and Solvent Content

Water containing alcohols and solvents may have high COD and require special process safety precautions. Its volume, concentration, recovery potential and compatibility with other wastewater streams are assessed together.

Highly concentrated solvent-containing streams are managed separately at source, while an appropriate treatment process is designed for the remaining dissolved organic load.

Oils, Emulsions and Surfactants

Oils, resins, polymers and surfactants used in manufacturing can create stable emulsions and heavy foaming. These components are controlled through suitable physicochemical separation and filtration processes.

Color and Recalcitrant Organic Compounds

Colored and persistent organic compounds from paint, pigment, additive and specialty chemical manufacturing may not be adequately removed through conventional treatment processes.

Hybrid photocatalytic oxidation and project-specific polishing stages reduce color, COD and recalcitrant organic loads.

High Salinity and Conductivity

Chemical reactions, neutralization and process chemicals may increase wastewater salinity and conductivity. Managing saline water separately from other streams protects treatment systems and enables assessment of suitable recovery options.

Variable pH and Temperature

Acidic and alkaline production streams can cause sudden changes in wastewater pH. Automatic monitoring, controlled equalization and dosing help stabilize treatment conditions.

04 · ENGINEERING DECISION MATRIX

Process Selection Based on Wastewater Characteristics

Wastewater characteristicProcess objective
Variable flow and pollutant loadsEqualization and controlled feeding
High or variable pHAutomatic pH control
High COD and TOCStaged reduction of organic load
Toxic or biocidal constituentsReduction of inhibitory effects
Alcohol and solvent contentSeparate management at source and suitable treatment
Oils and emulsionsPhysicochemical separation
Surfactants and foamingFoam control and process optimization
Color and recalcitrant organicsHybrid photocatalytic oxidation
High salinity and conductivitySeparate management and suitable recovery process
Metals and suspended solidsSettling, separation and filtration
Direct discharge targetCompliance with applicable effluent requirements
Biological treatment targetImproved biodegradability
Reuse targetFiltration and advanced treatment
05 · ADVANCED TREATMENT TECHNOLOGY

Hybrid Photocatalytic Oxidation for High COD and Toxicity

Analysis of colored solutions at different concentrations in a chemical laboratory

The hybrid photocatalytic oxidation technology developed by VERITAS ENVIRONMENT through TÜBİTAK-supported R&D is designed for on-site treatment of process wastewater with high disposal costs that is difficult to treat using conventional methods.

The system can be applied to achieve the following objectives:

Explore Hybrid Oxidation Technology ↗
Reduction of high COD and organic load
Breakdown of recalcitrant organic compounds
Support for removing color- and odor-forming substances
Reduction of biocidal and toxic effects
Improved wastewater biodegradability
Reduced inhibition of biological treatment
Compliance with discharge requirements
Reduced volume of waste sent off site
Improved capacity and performance of existing treatment plants

The hybrid photocatalytic oxidation system can operate as a standalone treatment unit for high-strength wastewater or as an advanced treatment stage complementing existing physicochemical and biological treatment plants.

06 · ON-SITE RECOVERY

On-Site Treatment of Wastewater Previously Sent Off Site

Sending water containing high COD, toxicity, solvents, biocidal agents or recalcitrant organic compounds off site incurs transportation, storage and disposal costs.

Through VERITAS ENVIRONMENT's on-site treatment approach, these streams can be treated in a controlled manner to achieve:

Direct discharge criteria,
Biological treatment acceptance conditions,
Safe feeding conditions for an existing treatment plant,
Reuse water quality in suitable projects.

POTENTIAL SAVINGS IN SUITABLE PROJECTS
80–90%

Depending on wastewater volume and pollution characteristics, existing transportation charges and disposal unit rates, suitable projects may achieve savings of approximately 80–90% on combined transportation and disposal costs.

Project-specific savings are calculated by evaluating annual wastewater volumes, current disposal invoices, system operating costs and target treatment performance together.

07 · COMPATIBILITY WITH EXISTING INFRASTRUCTURE

Integration into Existing Treatment Plants

VERITAS ENVIRONMENT evaluates existing physicochemical and biological treatment infrastructure, equipment capacities and actual operating data together.

The new process system can be integrated into an existing plant:

Filtration and process basins at a modern wastewater treatment plant
For pretreatment of high-strength production wastewater
Before biological treatment
After biological treatment as a polishing stage
As a standalone packaged system for specific production lines
Before UF and RO for treated-water reuse

This preserves usable infrastructure while strengthening the required treatment capacity, process safety and effluent performance.

08 · PLANT-SPECIFIC ENGINEERING

Plant-Specific Treatability and Process Design

Even plants in the same chemical or process industry can produce wastewater with very different characteristics. System design is therefore based on actual production and wastewater data rather than generic assumptions.

The following information is reviewed during the assessment:

Product groups and production formulations
Raw materials and process chemicals used
Safety data sheets
Production and cleaning procedures
Daily and annual wastewater volumes
High- and low-strength wastewater sources
COD, BOD, TOC, pH, conductivity, TSS and oil values
Solvents, alcohols, biocides and specialty organic compounds
Salinity, metals and temperature
Capacity and performance of the existing treatment system
Volumes transported off site and disposal costs
Discharge, biological treatment or reuse targets

These data are used to prepare water and pollutant load balances and determine treatment stages, equipment capacities, automation scenarios and operating costs.

09 · END-TO-END IMPLEMENTATION

Modular and Turnkey Chemical Wastewater Treatment Systems

VERITAS ENVIRONMENT delivers wastewater treatment and recovery projects for chemical and process industries with the following scope:

01Review of plant and production data
02Identification of wastewater sources
03Preparation of water and pollutant load balances
04Wastewater characterization assessment
05Process selection and capacity calculations
06Technical and economic feasibility
07Preparation of PFD and P&ID
08Engineering and 3D system design
09Equipment manufacturing
10Electrical systems and automation
11Integration with existing production and treatment infrastructure
12On-site installation and commissioning
13Operator training
14Remote monitoring through Cloud SCADA
15Performance and savings reporting

Systems can be designed as centralized or modular packaged solutions to suit production schedules and site conditions. Packaged units combine equipment, piping, instrumentation, electrical panels and automation components to shorten on-site installation times.

Industrial process equipment and piping for modular system integration
10 · DIGITAL PERFORMANCE

Cloud SCADA for Process and Performance Monitoring

Flow rate, pH, temperature, conductivity, chemical consumption, energy use and treatment performance can be monitored through Cloud SCADA.

Depending on the measurement and analysis infrastructure, the recorded operating data enable measurement and reporting of:

Volumes of wastewater treated
Reduction in off-site disposal volumes
Effluent water quality
Chemical and energy consumption
Recovered water and process resources
System operating hours
Equipment and process performance
Operating cost savings

These data provide verifiable technical evidence for industrial green transformation, environmental performance and sustainability reports, water and carbon footprint calculations, incentive applications and green financing initiatives.

VERITAS · CLOUD SCADA● PROCESS MONITORING
Flow ratem³/hour
Water qualityCOD / pH
EnergykWh
ILLUSTRATIVE DIAGRAM · ACTUAL DATA CONFIGURED PER PROJECT
11 · OPERATIONAL BENEFITS

Key Benefits for Your Facility

On-site treatment of process wastewater with high COD and toxicity
Reduction of recalcitrant organic compounds
Improved wastewater suitability for biological treatment
Controlled compliance with discharge requirements
Reduced volumes of wastewater transported off site
Potential transportation and disposal savings of up to 80–90%
Improved capacity and performance of existing treatment plants
Optimized chemical consumption and sludge generation
Reuse of suitable process water
Assessment of water, chemical and heat recovery opportunities
Rapid on-site integration with modular packaged systems
Remote monitoring through Cloud SCADA
Reportable treatment performance and operating savings
12 · FREQUENTLY ASKED QUESTIONS

Frequently Asked Questions About Chemical Industry Wastewater Treatment

How does VERITAS ENVIRONMENT treat chemical industry wastewater?

VERITAS ENVIRONMENT classifies wastewater by production source, organic load, toxicity and chemical constituents. Physicochemical treatment, hybrid photocatalytic oxidation, biological treatment and final polishing are combined to meet target effluent quality according to plant needs.

Can high-COD chemical wastewater be treated on site?

High-COD process wastewater can be treated on site through separate source management, equalization, physicochemical pretreatment and hybrid photocatalytic oxidation. The process is configured for direct discharge, biological treatment or reuse targets.

Can wastewater from different production processes be treated together?

Streams are first assessed for composition, concentration and mutual compatibility. Compatible waters are fed in a controlled manner to a common treatment line, while high-strength or specialty streams are managed separately. This optimizes treatment capacity and operating costs.

How is process water containing alcohols and solvents managed?

Water containing alcohols and solvents is collected separately at source. Concentrations, safety requirements and recovery potential are assessed before selecting an appropriate separation or treatment process. Remaining dissolved organic loads are reduced through project-specific advanced treatment stages.

Can chemical wastewater previously transported off site be treated at the plant?

On-site treatment can be designed based on wastewater characteristics and target effluent requirements. In suitable projects, wastewater can be treated to meet direct discharge or existing biological treatment acceptance criteria, significantly reducing off-site transport and disposal needs.

Can the system be integrated into an existing treatment plant?

VERITAS ENVIRONMENT evaluates existing physicochemical and biological treatment infrastructure and integrates the required advanced oxidation, filtration and recovery stages. Modular design allows system capacity and configuration to be adapted to site conditions.

What information is required for project design?

Preliminary assessment considers production capacity, product groups, chemicals used, cleaning procedures, daily wastewater volumes, analytical results, existing treatment facilities, off-site waste quantities, disposal costs and target effluent quality.

PRELIMINARY TECHNICAL AND ECONOMIC ASSESSMENT

Treat High-Cost Process Wastewater at Your Own Facility

A project-specific preliminary technical and economic study can be prepared by evaluating your chemical plant's production processes, wastewater sources, pollution characteristics, existing treatment infrastructure and disposal costs together.

Request a Chemical Industry Wastewater Treatment and Recovery Assessment ↗
Share
0
veritasadmin

veritasadmin

veritaş-logo-png
output-smallpngtools
Address

Istanbul University-Cerrahpasa Technopark Building, Office No: 71, Avcilar, Istanbul 34315, Turkey

📞 +90 (212) 812 68 92

✉️ [email protected]

Quick Links
  • Home
  • About Us
  • Technologies
  • R&D & Patents
  • Our Projects
  • E-Catalog
  • Contact Us
Follow Us